Operating temperature range
|
-10℃ to +60℃
|
|
Rating (max.)/(min.) (Resistive load)
|
1mA 5V DC/50μA 3V DC
|
|
Electrical performance
|
Output voltage
|
1V max. at 1mA 5V DC (Resistive load)
|
|
Insulation resistance
|
100MΩ min. 100V DC
|
|
Voltage proof
|
100V AC for 1 minute
|
|
Mechanical performance
|
Actuator strength
|
Pushing direction
|
20N
|
|
Pulling direction
|
20N
|
|
Vibration
|
10 to 55 to 10Hz/min., the amplitude is 1.5mm for all the frequencies, in the 3 direction of X, Y and Z for 2 hours respectively
|
|
Resistance to soldering heat
|
Manual soldering
|
350±10℃, 3(+1, 0)s
|
|
Reflow soldering
|
Refer to soldering conditions
|
|
Durability
|
Operating life without load
|
10,000 cycles
|
Operating life with load (Load: as ratings)
|
10,000 cycles
|
|
Environmental performance
|
Cold
|
-20±2℃ for 96h
|
|
Dry heat
|
85±2℃ for 96h
|
|
Damp heat
|
40±2℃, 90 to 95%RH for 96h
|
|
Example of Reflow Soldering Condition
|
|
|
Double heating method with infrared heater.
|
|
|
2. Temperature measurement
|
|
Thermocouple 0.1 to 0.2 Φ CA (K) or CC (T) at soldering portion (copper foil surface). A heat resisting tape should be used for fixed measurement.
|
|
|
|
|
(1) The condition mentioned above is the temperature on the mounting surface of a PC board. There are cases where the PC board's temperature greatly differs from that of the switch, depending on the PC board's material, size, thickness, etc. Care should be taken to prevent the switch's surface temperature from exceeding 260℃.
|
|
|
(2) Soldering conditions differ depending on reflow soldering machines. You are requested to verify the soldering conditions thoroughly beforehand.
|
|
|
|
|
|