Operating temperature range
|
-10℃ to +60℃
|
|
Rating (max.)/(min.) (Resistive load)
|
0.1A 12V DC/50μA 3V DC
|
|
Electrical performance
|
Initial contact resistance (Intial performance/After lifetime)
|
1Ω max./1Ω max.
|
|
Insulation resistance
|
100MΩ min. 100V DC
|
|
Voltage proof
|
100V AC for 1 minute
|
|
Mechanical performance
|
Robustness of terminal
|
5N for 1 minute
|
|
Actuator strength
|
Pushing direction
|
100N
|
|
Vibration
|
10 to 55 to 10Hz/min., the amplitude is 1.5mm for all the frequencies, in the 3 direction of X, Y and Z for 2 hours respectively
|
|
Resistance to soldering heat
|
Manual soldering
|
350±10℃, 3(+1, 0)s
|
|
Reflow soldering
|
Refer to soldering conditions
|
|
Durability
|
Operating life without load
|
10,000 cycles
|
Operating life with load (Load: as ratings)
|
10,000 cycles (0.1A 12V DC)
|
|
Environmental performance
|
Cold
|
-20±2℃ for 96h
|
|
Dry heat
|
85±2℃ for 96h
|
|
Damp heat
|
40±2℃, 90 to 95%RH for 96h
|
|
Example of Reflow Soldering Condition
|
|
|
Double heating method with infrared heater.
|
|
|
2. Temperature measurement
|
|
Thermocouple 0.1 to 0.2 Φ CA (K) or CC (T) at soldering portion (copper foil surface). A heat resisting tape should be used for fixed measurement.
|
|
|
|
|
(1) The condition mentioned above is the temperature on the mounting surface of a PC board. There are cases where the PC board's temperature greatly differs from that of the switch, depending on the PC board's material, size, thickness, etc. Care should be taken to prevent the switch's surface temperature from exceeding 240℃.
|
|
|
(2) Soldering conditions differ depending on reflow soldering machines. Prior verification of soldering condition is highly recommended.
|
|
|
|
|
|