Operating temperature range
|
-40℃ to +85℃
|
|
Maximum operating current (Resistive load)
|
10mA
|
|
Electrical performance
|
Ratings
|
10mA 5V DC
|
|
Output signal
|
Output of A and B signals, proportionate to phase difference
|
|
Insulation resistance
|
100MΩ min. 250V DC
|
|
Voltage proof
|
300V AC for 1 minute
|
|
Mechanical performance
|
Push-pull strength
|
100N
|
|
Resistance to soldering heat
|
Manual soldering
|
350℃ max. 3s max.
|
|
Reflow soldering
|
Refer to soldering conditions
|
|
Durability
|
Rotational life
|
100,000 cycles
|
|
Environmental performance
|
Cold
|
-40±3℃ for 240h
|
|
Dry heat
|
85±3℃ for 240h
|
|
Damp heat
|
60±2℃, 90 to 95%RH for 240h
|
|
Push-on switch specifications
|
Circuit / number of contact
|
Single pole and single throw (Push-on)
|
|
Travel
|
0.5±0.3mm
|
|
Operating force
|
5±2N
|
|
Ratational torque
|
0.1A 5V DC
|
|
Contact resistance
|
100mΩ for initial period; 200mΩ after rotational life
|
|
Operating life
|
1,000,000 times min.
|
|
Example of Reflow Soldering Condition
|
|
|
Double heating method with infrared heater.
|
|
|
2. Temperature measurement
|
|
Thermocouple 0.1 to 0.2 Φ CA (K) or CC (T) at soldering portion (copper foil surface). A heat resisting tape should be used for fixed measurement.
|
|
|
|
|
(1) The condition mentioned above is the temperature on the mounting surface of a PC board. There are cases where the PC board's temperature greatly differs from that of the switch, depending on the PC board's material, size, thickness, etc. Care should be taken to prevent the switch's surface temperature from exceeding 260℃.
|
|
|
(2) Soldering conditions differ depending on reflow soldering machines. You are requested to verify the soldering conditions thoroughly beforehand.
|
|
|
(3) Ask us for the specifications of lead-free products.
|
|
|
|
|
|